Human AGT ELISA Kit

Customer Reviews
Cat. No. / Size
Price
Availability
Qty
CEA-B291-96tests
$590.00

Product Details

  • Product Overview

    The Human AGT ELISA Kit is a ready‑to‑use immunoassay kit specifically designed for the quantification of native and recombinant human AGT in biological samples, including serum and plasma. Our ELISA kit offers multiple advantages:

  • Product Specifications

    Assay Type
    Sandwich-ELISA
    Analyte
    AGT
    Format
    96-wells plate breakable into 12 x 8 wells strips
    Reactivity
    Human
    Sensitivity
    50 pg/mL
    Assay Time
    2.75 hr
    Sample volume
    50 μL
    Range
    62.5 pg/mL-4000 pg/mL
    Sample Type
    For the quantitative determination of human AGT in serum, plasma and cell supernatant.

    Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.

  • Application

    The kit is developed for the quantification of native and recombinant human AGT in serum, plasma.

    It is for research use only.

  • Workflow

    AGT Workflow

  • Storage

    Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

  • Materials Provided

    ID
    Components
    Size
    CEA291-C01
    Pre-coated Anti-AGT Antibody Microplate
    1 plate
    CEA291-C02
    Human AGT Standard
    500 ng/mL×2
    CEA291-C03
    Biotin-Anti-AGT Antibody Con. Solution
    100 μL
    CEA291-C04
    Biotin-Antibody Dilution Buffer
    8 mL
    CEA291-C05
    Streptavidin-HRP Con. Solution
    500 μL
    CEA291-C06
    Streptavidin-HRP Dilution Buffer
    15 mL
    CEA291-C07
    20× Washing Buffer
    50 mL
    CEA291-C08
    Sample Dilution Buffer
    15 mL×2
    CEA291-C09
    Substrate Solution
    12 mL
    CEA291-C10
    Stop Solution
    6 mL
  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Customers Also Viewed

Performance Data

  • Typical Data 

    Please refer to DS document for the assay protocol.

     AGT TYPICAL DATA

    For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of AGT is less than 50 pg/mL.

Validation
  • Sample Values

    Twenty-four human serum samples were evaluated for the concentrations of human AGT in assay. The detection AGT rate of the samples was 100%, the range was 22.417-127.481 μg/mL, and the mean detectable value was 49.099 μg/mL.

     AGT SAMPLE VALUES
  • Intra-Assay Statistics

    Eight replicates of each of 3 samples containing different AGT concentrations were tested in one assay. Acceptable criteria: CV<10%.

     AGT INTRA-ASSAY STATISTICS
  • Inter-Assay Statistics

    Three samples containing different concentrations of AGT were tested in independent assays. Acceptable criteria: CV<15%.

     AGT INTER-ASSAY STATISTICS

Customer Reviews
Writing Reviews

Recent Advances

 
Drug Candidate Licensing
More
  • Basic Product Information
  • Product Details
  • Customers Also Viewed
  • Performance Data
  • Customer Reviews