Mon panier

LER Sample Dilution Buffer

Avis des utilisateurs
Numéro de produit/spécification
Spéc. emballage
Prix
Qté
RES-A129-1box
15mL x 5bottles
$50.00
ETA of in-stock products:2 business days
Total des articles Montant du produit$ 0

Détails du produit

  • Materials Provided

    ID
    Components
    Size
    RES-A129-C01
    LER Sample Dilution Buffer
    15mL

  • Application

    Low Endotoxin Recovery (LER) refers to the phenomenon where the measured endotoxin concentration in a sample is lower than its actual level, which is a common interference issue in both Limulus Amebocyte Lysate (LAL) and recombinant C-factor assays for endotoxin detection; matrix components such as citric acid, ethylenediaminetetraacetic acid (EDTA), Tween 20 and Tween 80 are common triggers of LER, as these substances can either bind to endotoxins, inhibit the enzymatic reaction of LAL reagents or block the activation of recombinant C-factor, resulting in inaccurate and underestimated endotoxin detection results. LER Sample Dilution Buffer can be added to samples containing the aforementioned interfering substances, which effectively mitigates the LER interference and ensures the accuracy of endotoxin quantification in both LAL and recombinant C-factor assays, with an endotoxin content of <0.005 EU/mL that eliminates the risk of introducing exogenous endotoxin contamination during sample preparation.

    It is for research use only.

  • Features

    1. LER sample dilution buffer: <0.005 EU/mL endotoxin.
    2. Small pack (15 mL×5 bottles ) to avoid exogenous contamination.
  • Storage

    Store at room temperature.

  • ACRO Quality Management System

    1. QMS(ISO, GMP)
    2. Quality Advantages
    3. Quality Control Process

Les clients ont également consulté

Affichage des données

  • Typical Data 

    Please refer to DS document for the assay protocol.

     - TYPICAL DATA

    Endotoxin recovery in 1mM EDTA samples. LER buffer effectively mitigates EDTA-induced endotoxin interference, restoring spiked recovery to 119% (vs. 38% in water).

  •  - TYPICAL DATA

    Endotoxin recovery in 0.05% Tween-80 samples. LER buffer reverses Tween-80-mediated endotoxin masking, achieving 150% spiked recovery (vs. 35% in water).

  •  - TYPICAL DATA

    Endotoxin recovery in 0.01% Tween-20 samples. LER buffer eliminates Tween-20-induced endotoxin interference, improving spiked recovery to 137% (vs. 38% in water).