    Assay TypeSandwich-ELISA
    AnalyteIL-10
    Format96T
    ReactivityHuman
    Regulatory StatusRUO
    Sensitivity<6.25 pg/mL
    Standard Curve Range6.25 pg/mL-200 pg/mL
    Assay Time2 hr 50 min
    Suitable Sample TypeFor detection and quantitative determination of GMP human IL-10 in samples from CAR-T product preparation processing.
    Sample volume100 uL
  • Background
    IL-10 is an anti-inflammatory cytokine. It maintains the balance of the immune response, allowing the clearance of infection while minimizing damage to the host by inhibits the activity of Th1 cells, NK cells, and macrophages. The receptor for IL10 is a heterotetramer complex comprising two IL10Rα molecules and two IL10Rβ molecules .
  • Application

    Human Interleukin-10 (IL-10) ELISA Kit (Residue Testing) was developed for the detection and quantitative determination of GMP human IL-10 in samples from CAR-T product preparation processing.

    It is for research use only.

  • Reconstitution
    Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.
  • Storage
    The unopened kit is stable for 12 months from the date of manufacture if stored at 2°C to 8°C.

    The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

    Materials Provided
    IDComponentsSize
    CRS008-C01Pre-coated Anti-IL-10 Antibody Microplate1 plate
    CRS008-C02Human IL-10 Standard20 μg
    CRS008-C03Biotin-Anti-IL-10 Antibody50 μL
    CRS008-C04Streptavidin-HRP50 μL
    CRS008-C0510×Washing Buffer 50 mL
    CRS008-C062×Dilution Buffer50 mL
    CRS008-C07Substrate Solution12 mL
    CRS008-C08Stop Solution7 mL
  • Assay Principles
    This assay kit employs a standard sandwich-ELISA format, providing a rapid detection of Human IL-10. The kit consists of Pre-coated Anti-IL-10 Antibody Microplate and Human IL-10 Standard and Biotin-Anti-IL-10 Antibody and Streptavidin-HRP and buffers.

    Your experiment will include 6 simple steps:

    a) Bring all reagents to room temperature(20℃-25℃) before use.

    b) Add your sample to the plate and take the Human IL-10 as standard. The samples and standard are diluted by Dilution Buffer.

    c) Wash the plate and add the Biotin-Anti-IL-10 Antibody diluted by Dilution Buffer to the plate.

    d) Wash the plate and add the Streptavidin-HRP diluted by Dilution Buffer to the plate.

    e) Wash the plate and add TMB.

    f) Stop the substrate reaction by adding diluted acid. Absorbance (OD) is calculated by the absorbance at 450 nm minus the absorbance at 630 nm to remove background disturbance before statistical analysis. The OD Value reflects the amount of bound protein.

Typical Data Please refer to DS document for the assay protocol.
 IL-10 TYPICAL DATA

For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.

Validation
Dilution Linearity

To assess the linearity of the assay, samples spiked with high concentrations of human IL-10 were serially diluted with calibrator diluent to produce samples with values within the dynamic range of the assay.

 IL-10 DILUTION LINEARITY
Intra-Assay Statistics

Three samples of known concentration were tested ten times on one plate to assess intra-assay precision.

 IL-10 INTRA-ASSAY STATISTICS
Inter-Assay Statistics

Three samples of known concentration were tested in three separate assays to assess inter-assay precision.

 IL-10 INTER-ASSAY STATISTICS
Recovery

Five parts of blank T cell culture supernatant were added with different concentrations of human IL-10, and the T cell culture supernatant without human IL-10 was used as background to calculate the recovery rate. The range of the recovery rate is 86.6-95.0%, and the average recovery is 91.9%.

 IL-10 RECOVERY
  • Clinical and Translational Updates

Comments (0)


ETA des produits en stock: 2 jours ouvrables

Price(EUR) : €350.00

Promotion & Exhibitions



Drug Development Status

  • Number of Launched Drugs:0 Details
  • Number of Drugs in Clinical Trials:4 Details
  • Latest Research Phase:Phase 3 Clinical

Datasheet & Documentation

Request for DMF
DMF (Drug Master File)

Related Products

New Product Launch

Questions & Comments

This web search service is supported by Google Inc.

totop

Laisser un message